SDS Repository

sds

Collection
Penray
Description
 
Tags
Search Tag
Filename
2420msds.PDF
Source
 
Full Text
PRODUCT AND COMPANY IDENTIFICATION1 Manufacturer The Penray Companies, Inc. 440 Denniston Ct.Wheeling, IL 60090 Contact:Telephone Number:FAX Number:E-Mail:Web EH&S Manager847-459-5000847-459-5043 www.penray.com EMERGENCY PHONE NUMBER (800) 752-7869 NFPA 704M RATING : HEALTH:2 FIRE:4 REACTIVITY: 0 SPECIAL: O=INSIGNIFICANT 1=SLIGHT 2=MODERATE 3=HIGH 4=EXTREME PENRAY PRESSURIZED UNIVERSAL FUEL INJECTOR TUNE UP 242001/16/20082420AEROSOL FUEL INJECTOR CLEANER CONTAINING ORGANIC SOLVENTSF618 Product Name:Revision Date:MSDS Number:Common Name:Chemical Formula: COMPOSITION/INFORMATION ON INGREDIENTS2 INGREDIENT CAS NUMBER PERCENT WEIGHT XYLENE 1330-20-7 75% - 95% TOLUENE 108-88-3 4% - 24% SEVERLY HYDROTREATED HEAVY NAPHTHENIC DISTILLATE 64742-52-5 <2% NITROGEN 7727-37-9 <2% HAZARDS IDENTIFICATION3 Skin absorption and inhalationRoute of Entry: Lungs, kidneys, liver and nervous system.Target Organs: Respiratory irritation and dizzinessInhalation: Prolonged contact with skin can cause irritation. Repeated skin contact may cause persistent irritationand dermatitisSkin Contact: Will cause irritation upon contact.Eye Contact: Product may cause discomfort, nausea,vomiting and diarrhea.Ingestion: CARCINOGENICITY: Product is not considered a carcinogen by OSHA, NTP or IARC. MEDICAL CONDITIONS: Pre-existing eye or skin conditions may be aggravated by over-exposure to this product. PENRAY PRESSURIZED UNIVERSAL FUEL INJECTOR TUNE UP 2420 Material Safety Data Sheet Revision Date: 01/16/2008MSDS Number: 2420 Page of1 4 MSDS THE PENRAY COMPANIES, INC. FIRST AID MEASURES4 Remove to fresh air. If not breathing, give artificial respiration. Seek medical attention. Inhalation hazardunlikely due to low volatility of product.Inhalation: Wash area with soap and water. seek medical attention if irritation persistsSkin Contact: Immediately flush eyes with plenty of water for 15 minutes. Seek medical attention.Eye Contact: DO NOT induce vomiting. Only give CONSCIOUS victim two glasses of water and seek medical attention.NEVER give UNCONSCIOUS anything by mouth.Ingestion: FIRE FIGHTING MEASURES5 EXTINGUISHING MEDIA: Carbon Dioxide ( CO2) Dry Chemical, Foam.UNUSUAL FIRE AND EXPLOSION HAZARDS: Vapors are heavier than air and can collect in low areasFIRE FIGHTING INSTRUCTIONS: Containers can build up pressure if exposed to fire. Containers should be cooled withwater supply.FIRE FIGHTING EQUIPMENT: Self- contained breathing apparatus with full face piece operated in positive pressure mode. 1-45 FTCCFlash Point:Flash Point Method: ACCIDENTAL RELEASE MEASURES6 SPILL/LEAK PROCEDURES: Notify safety personnel ,evacuate all unnecessary personnel and provide adequate ventilation. If feasible, and without risk,clean-up personnel should stop leak. All clean up personnel should wear proper personal protective equipment. SMALL SPILLS:Clean with inert absorbent and place in recovery drums for disposal. LARGE SPILLS: Dike to prevent further migration of material. DO NOT release into waterways or sewers. Follow applicable federal and state regulations. HANDLING AND STORAGE7 Wash thoroughly after handling. Do not get into eyes, on skin or on clothing.. Do not smokewhile using this product.Do not use near excessive heat, sparks, or open flame.Handling Precautions: Store in clean, dry locations awat from excessive heat. Store in areas designated for thestorage of Level III aerosols according to NFPA 30B ( Manufacturing and Storage of AerosolProducts.) Storage Requirements: EXPOSURE CONTROLS/PERSONAL PROTECTION8 Eye wash station and safety shower.Strong general ventilation or local exhaust.Engineering Controls: EYE: Chemical splash goggles with indirect or no ventilation.SKIN :Chemical resistant gloves, such as nitrile.RESPIRATORY: Organic vapor air purifying respiator if vapors are a nuisance or if theconcentrations are above PEL or TLV. Protective Equipment: Never eat, drink or smoke in work area Exposure Guidelines/Other: PENRAY PRESSURIZED UNIVERSAL FUEL INJECTOR TUNE UP 2420 Material Safety Data Sheet Revision Date: 01/16/2008MSDS Number: 2420 Page of2 4 MSDS THE PENRAY COMPANIES, INC. PHYSICAL AND CHEMICAL PROPERTIES9 Colorless liquidAppearance: liquidPhysical State: Organic solvent odorOdor:pH: BT 22-181 mmHGVapor Pressure: >1Vapor Density: BT 220-440 FBoiling Point:Freezing/Melting Pt.: Partially soluble in waterSolubility: BT 0.785 - 0.870Spec Grav./Density: 100 %VOC: STABILITY AND REACTIVITY10 Material is stable.Stability: Excessive heat and open flame.Conditions to avoid: Strong oxidizing agents.Materials to avoid (incompatability): Carbon Monoxide and Carbon DioxideHazardous Decomposition products: Cannot occur.Hazardous Polymerization: TOXICOLOGICAL INFORMATION11 LD50 Toluene: 7.71 g/kg (oral) Xylene: 7.53 g/kg (oral) ECOLOGICAL INFORMATION12 No data. DISPOSAL CONSIDERATIONS13 As a waste, this product in its raw form DOES MEET the criteria of a hazardous waste as defined by RCRA (40 CFR 361). Allused and unused product and container should be disposed of in accordance with all applicable federal,state and localregulations. Do not dump in drains, sewers, on the ground or into any body of water. TRANSPORT INFORMATION14 DOMESTIC: CONSUMER COMMODITY ORM-D EXPORT: UN 1950, AEROSOL DISPENSERS, CLASS 2.1 Limited Quantity PENRAY PRESSURIZED UNIVERSAL FUEL INJECTOR TUNE UP 2420 Material Safety Data Sheet Revision Date: 01/16/2008MSDS Number: 2420 Page of3 4 MSDS THE PENRAY COMPANIES, INC. REGULATORY INFORMATION15 U.S. FEDERAL REGULATIONS OSHA: Considered to be a hazardous material as defined by 29CFR1910.1200 EPA SARA TITLE III Section 311-312 (40CFR370): If stored in excess of the threshold quantities, this product should be reported as a(n): IMMEDIATE (acute) HEALTH HAZARD DELAYED (chronic) HEALTH HAZARD FIRE HAZARD SUDDEN RELEASE HAZARD Section 313(40CFR372) This product contains ingredients which are subject to the reporting requirements of SARA 313: Toluene: 13.8559% Xylene: 84.0650% This diesel fuel additive complies with the federal low sulfur content requirements for use in diesel motor vehicles and nonroad engines. OTHER INFORMATION16 CALIFORNIA PROPOSITION 65: This product contains ingredients which are on the current Proposition 65 list, and are known to the State of California to cause cancer, birth defects and other reproductive harm.: Toluene Notes: NG= NOT GIVEN BT= BETWEEN <= LESS THAN >= GREATER THAN USERS RESPONSIBILITY;This MSDS provides environmental, health and safety information. This product is to be used in applications consistent with our product literature and container label. Individuals handling this product should be informed to the recommended safety precautions and have access to this MSDS. Please contact your local sales representative or our EH&S Department for further information. END OF MSDS END OF MSDS DOCUMENT PENRAY PRESSURIZED UNIVERSAL FUEL INJECTOR TUNE UP 2420 Material Safety Data Sheet Revision Date: 01/16/2008MSDS Number: 2420 Page of4 4 MSDS THE PENRAY COMPANIES, INC.