SDS Repository

sds

Collection
Permatex
Description
 
Tags
Search Tag
Filename
80052msds.pdf
Source
 
Full Text
Material Safety Data Sheet 1. PRODUCT IDENTIFICATION Product Name: 68DA FAST BREAK SUPER PENETRANT 12OZ AE Item No: 80052 Product Type: Penetrant 2. COMPOSITION/INFORMATION ON INGREDIENTS Component: Weight% ACGIH; TLV-TWA OSHA PEL MINERAL OIL 8042-47-5 30-60 5 mg/m3 Not listed DISTILLATES (PETROLEUM), HYDROTREATED LIGHT 64742-47-8 15-40 Not listed Not listed SOLVENT NAPHTHA (PETROLEUM), LIGHT ALIPH. 64742-89-8 10-30 Not listed Not listed PROPANE 74-98-6 <10 1000 ppm 1000 ppm; 1800 mg/m3 BUTANE 106-97-8 <10 1000 ppm 800 ppm; 1900 mg/m3 3. HAZARDS IDENTIFICATION Toxicity: May cause eye, skin and respiratory irritation. Aspiration hazard if swallowed. Primary Routes of Entry: Eye and skin contact, ingestion, inhalation Signs and Symptoms of Exposure: Excessive overexposure may cause giddiness, dizziness, headache, nausea and in extreme cases, unconsciousness and respiratory depression. Overexposure may cause eye and skin redness. Aggravated Medical Condition: Persons with respiratory problems such as emphysema and asthma should avoid inhalation. 4. FIRST AID MEASURES Ingestion: If swallowed, do not induce vomiting - seek medical advice. Never give anything by mouth to an unconscious person. Inhalation: Move to fresh air in case of accidental inhalation of vapours. If signs of irritation or toxicity occur seek medical attention. Skin Contact: Wash off with soap and water. If skin irritation persists, call a physician. Eye Contact: In case of contact, immediately flush eyes with plenty of water for at least 15 minutes and get medical attention if irritation persists. 5. FIRE FIGHTING MEASURES Flash Point ?F(C?): Flammable aerosol based on flame projection test Recommended Extinguishing Media: Carbon Dioxide, Dry Chemicals, Foam. Special Fire-Fighting Procedures: Firefighters should wear self-contained breathing apparatus. Keep containers cool. Use equipment or shielding required to protect against bursting or venting of containers. Hazardous Products of Combustion: Oxides of carbon Unusual Fire/Explosion Hazards: Contents under pressure. Exposure to temperatures over 120 degrees F. may cause bursting or venting. Lower Explosive Limit: Not determined Upper Explosive Limit: Not determined 6. ACCIDENTAL RELEASE MEASURES Spill Procedures: Eliminate all sources of ignition. Maintain good ventilation. Take up with an inert absorbent. Store in a closed waste container until disposal. 1 of 3 ITW Permatex 10 Columbus Blvd. Hartford, CT 06106 USA Telephone: 1-87-Permatex (877) 376-2839 Emergency: 800-255-3924 (ChemTel) International Emergency: 00+ 1+ 813-248-0585 7. HANDLING AND STORAGE Storage: Store away from heat, sparks or open flame. Do not store at temperatures above 100?F (38?C). Handling: Do not use near heat, sparks or open flame. Do not puncture or incinerate container. Use in a well ventilated area. Avoid contact with skin and eyes. Wash thoroughly after handling. 8. EXPOSURE CONTROLS/PERSONAL PROTECTION Eyes: Safety glasses. Skin: Neoprene or nitrile gloves recommended. Ventilation: Where reasonably practicable this should be achieved by the use of local exhaust ventilation and good general extraction. Respiratory Protection: An approved organic vapor respirator should be worn when exposures are expected to exceed the applicable limits. 9. PHYSICAL AND CHEMICAL PROPERTIES Appearance: Black liquid Odor: Solvent Boiling Point: >100?F pH: Does not apply Solubility in Water: Insoluble Specific Gravity: 0.835-0.845 VOC(Wt.%): 24.89% Vapor Pressure: Not determined Vapor Density (Air=1): >1 Evaporation Rate: <1 (butyl acetate = 1) 10. STABILITY AND REACTIVITY Chemical Stability: Stable at normal conditions Hazardous Polymerization: Will not occur Incompatabilities: Strong oxidizers Conditions to Avoid: Keep away from heat, sparks and open flame. - No smoking Hazardous Products of Combustion: Oxides of carbon 11. TOXICOLOGICAL INFORMATION See Section 3 12. ECOLOGICAL INFORMATION No data available 13. DISPOSAL CONSIDERATIONS Recommended Method of Disposal: Disposal should be made in accordance with federal, state and local regulations. This container may be recycled in aerosol recycling centers. Before offering for recycling, empty the can by using the product according to the label. If recycling is not available, wrap the container and discard in the trash. US EPA Waste Number: D001 as per 40CFR 261.21 14. TRANSPORTATION INFORMATION DOT (49CFR 172) U.S. Department of Transportation - DOT - 49 CFR (Ground) DOT Shipping Name: Aerosols, Limited Quantity Hazard Class: Class 2.1 UN/ID Number: UN 1950 IATA (Air) Proper Shipping Name: Consumer Commodity Class or Division: Class 9 UN/ID Number: ID 8000 IMDG (Vessel) Proper Shipping Name: Aerosols, Limited Quantity Hazard Class: Class 2.1 UN Number: UN 1950 68DA FAST BREAK SUPER PENETRANT 12OZ AE Product Name: Item No. 80052 Marine Pollutant: None 15. REGULATORY INFORMATION SARA 313 Chemicals: The following component(s) is listed as a SARA Section 313 Toxic Chemical. NONE California Proposition 65: WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm TSCA Inventory Status: All components of this product are listed (or exempt) on the EPA TSCA inventory. 16. OTHER INFORMATION Estimated NFPA Rating: HEALTH 1, FLAMMABILITY 4 , REACTIVITY 0. Estimated HMIS Classification: HEALTH 1, FLAMMABILITY 4, PHYSICAL HAZARD 0 (NFPA is a registered trademark of the National Fire Protection Association) (HMIS is a registered trademark of the National Paint and Coatings Association) Company: ITW Permatex 10 Columbus Blvd. Hartford, CT USA 06106 Product Name: Revision Number: 1 Item No. 80052 Telephone No.: 1-87-Permatex (877) 376-2839 Prepared By: Denise Boyd, Manager-Environmental, Health & Safety 68DA FAST BREAK SUPER PENETRANT 12OZ AE Revision Date: November 20, 2013