SDS Repository

sds

Collection
AC Delco
Description
 
Tags
Search Tag
Filename
10-4070.pdf
Source
 
Full Text
SECTION 1: Identification of the substance/mixture and of the company/undertaking 1.1. Product identifier Product code 912 Product name LSC TRANSMISSION FLUID 12-301 Synonyms SL 12-301 BW: 118127 1.2. Relevant identified uses of the substance or mixture and uses advised against Recommended Use Lubricant. Uses advised against No information available 1.3. Details of the supplier of the safety data sheet For further information, please contact Contact Point HSE Advisor Email address This email address is being protected from spambots. You need JavaScript enabled to view it. Company Phone Number +46 8 429 60 00 1.4. Emergency telephone number Emergency telephone - ?45 - (EC)1272/2008 Europe 112 Czech Republic +420 224 91 92 93/+420 224 91 54 02 (Poison Information) Denmark +45 82 12 12 12 (Poison Information) Finland +358 09 471 977 (Poison Information) Latvia + 371 7042468 (Poison Information) Lithuania +370 5 236 20 52 (Poison Information) Norway +47 22 59 13 00 (Poison Information) Poland +48 426 314 502 (Poison Information) Slovakia + 421 2 5465 2307 (Poison Information) Sweden +46 8 33 70 43 (Emergency Responce Center) Estonia +372 626 9390 (Poison Information) SECTION 2: Hazards identification 2.1. Classification of the substance or mixture Classification according to Regulation (EC) No 1272/2008 [CLP] This mixture is classified as not hazardous according to regulation (EC) 1272/2008 [GHS] Classification according to 67/548/EEC or 1999/45/EC This product does not meet the classification requirements of the current legislation _____________________________________________________________________________________ Issue Date 12-Apr-2013 Revision date 10-Apr-2015 Version 1 Company Name Statoil Fuel & Retail Lubricants Sweden AB, Box 194, 149 22 Nyn?shamn, Sweden, +46 8 429 60 00 Safety Data Sheet Supplier Statoil Fuel & Retail Lubricants Sweden AB, Box 194, 149 22 Nyn?shamn, Sweden +46 8 429 60 00 Page 1 / 10 10-4070, 88863349 - ACDelco Manual Transmission Fluid 75W-90 GL-4 _____________________________________________________________________________________ Full text of R-phrases: see section 16 2.2. Label elements This mixture is classified as not hazardous according to regulation (EC) 1272/2008 [GHS] Signal Word None Contains C14-18 alpha-olefin epoxide, reaction products with boric acid May produce an allergic reaction EUH210 - Safety data sheet available on request 2.3. Other hazards No information available SECTION 3: Composition/information on ingredients 3.1 Substances Only hazardous substances above thresholds are shown below Chemical name EC No CAS No weight-% Classification according to 67/548/EEC or 1999/45/EC Classification according to Regulation (EC) No. 1272/2008 [CLP] REACH registration number zinc bis[O,O-bis(2-ethylhex yl)] bis(dithiophosphate) 224-235-5 4259-15-8 1-5% Xi;R41 N;R51/53 Aquatic Chronic 2 (H411) Eye Dam. 1 (H318) 01-2119493635-27 Full text of R-phrases: see section 16 Full text of H- and EUH-phrases: see section 16 SECTION 4: First aid measures 4.1. Description of first aid measures General advice If symptoms persist, call a physician. Do not breathe dust/fume/gas/mist/vapors/spray. Do not get in eyes, on skin, or on clothing. Eye Contact Wash with plenty of water. If eye irritation persists: get medical advice/attention. Skin Contact Remove contaminated clothing and shoes. Wash skin with soap and water. Wash contaminated clothing before reuse. Ingestion Clean mouth with water. Do NOT induce vomiting. Potential for aspiration if swallowed. Get medical attention. Inhalation Remove to fresh air. If symptoms persist, call a physician. _____________________________________________________________________________________ Revision date 10-Apr-2015 Page 2 / 10 LSC TRANSMISSION FLUID 12-301 _____________________________________________________________________________________ Self-protection of the first aider Use personal protective equipment as required. 4.2. Most important symptoms and effects, both acute and delayed Symptoms None under normal use conditions. 4.3. Indication of any immediate medical attention and special treatment needed Note to physicians Treat symptomatically. SECTION 5: Firefighting measures 5.1. Extinguishing media Suitable extinguishing media Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Use CO2, dry chemical, or foam. Unsuitable extinguishing media Do not use a solid water stream as it may scatter and spread fire. 5.2. Special hazards arising from the substance or mixture Special Hazard Incomplete combustion and thermolysis may produce gases of varying toxicity such as carbon monoxide, carbon dioxide, various hydrocarbons, aldehydes and soot. These may be highly dangerous if inhaled in confined spaces or at high concentration. Cool drums with water spray. 5.3. Advice for firefighters Special protective equipment for fire-fighters Wear self contained breathing apparatus for fire fighting if necessary. SECTION 6: Accidental release measures 6.1. Personal precautions, protective equipment and emergency procedures Use personal protection recommended in Section 8. Extremely slippery when spilled. 6.2. Environmental precautions Prevent further leakage or spillage if safe to do so. Prevent entry into waterways, sewers, basements or confined areas. Local authorities should be advised if significant spillages cannot be contained. 6.3. Methods and material for containment and cleaning up Contain and collect spillage with non-combustible absorbent material, (e.g. sand, earth, diatomaceous earth, vermiculite) and place in container for disposal according to local / national regulations (see Section 13). Soak up with inert absorbent material (e.g. sand, silica gel, acid binder, universal binder, sawdust). 6.4. Reference to other sections Other information See Section 12: Ecological information. _____________________________________________________________________________________ Revision date 10-Apr-2015 Page 3 / 10 LSC TRANSMISSION FLUID 12-301 _____________________________________________________________________________________ SECTION 7: Handling and storage 7.1. Precautions for safe handling Advice on safe handling Handle in accordance with good industrial hygiene and safety practice. Use personal protective equipment as required. Avoid contact with skin, eyes or clothing. Extremely slippery when spilled. General hygiene considerations Handle in accordance with good industrial hygiene and safety practice. 7.2. Conditions for safe storage, including any incompatibilities Storage Conditions Store in a dry place. Store in a closed container. Protect from moisture. 7.3. Specific end use(s) Specific use(s) Lubricant. SECTION 8: Exposure controls/personal protection 8.1. Control parameters Chemical name Sweden Denmark Norway Finland Estonia Oil mist/smoke NGV 8 h: 1 mg/m?, KTV 15 min: 3 mg/m? 8h: 1 mg/m? 8h: 1 mg/m? 8h: 5 mg/m? TWA 8h: 1 mg/m? Chemical name Latvia Lithuania Poland Russia Slovakia Oil mist/smoke 8h: 5 mg/m? IPRV 8h: 1 mg/m?, TPRV 15 min: 3 mg/m? NDS: 8h: 5 mg/m?, NDSCh, 15 min, 10 mg/m? 5 mg/m? 8h: 5 mg/m? Chemical name Czech Republic Germany Hungary Bulgaria Ukraine Oil mist/smoke PEL: 5 mg/m? NPK-P: 10 mg/m? - - - - Derived No Effect Level (DNEL) No information available Predicted No Effect Concentration (PNEC) No information available. 8.2. Exposure controls Engineering controls None under normal use conditions. Personal protective equipment Eye/face Protection Wear safety glasses with side shields (or goggles). Hand protection Wear protective nitrile rubber gloves, Because specific work environments and material handling practices vary, safety proceduresshould be developed for each intended application. The correct choice of protective gloves depends upon the chemicals being handled, and the conditions of work and use. Most gloves provide protection for only a limited time before they must be discarded and replaced (even thebest chemically resistant gloves will break down after repeated chemical exposures).Gloves should be chosen in consultation with the supplier / manufacturer and taking account ofa full assessment of the working conditions. Body protection Wear suitable protective clothing. Respiratory Protection No protective equipment is needed under normal use conditions. If exposure limits are exceeded or irritation is experienced, ventilation and evacuation may be required, In case of inadequate ventilation wear respiratory protection. _____________________________________________________________________________________ LSC TRANSMISSION FLUID 12-301 Page 4 / 10 Revision date 10-Apr-2015 _____________________________________________________________________________________ General hygiene considerations Handle in accordance with good industrial hygiene and safety practice. Environmental exposure controls Prevent product from entering drains. Local authorities should be advised if significant spillages cannot be contained. SECTION 9: Physical and chemical properties 9.1. Information on basic physical and chemical properties Physical State Liquid 9.2. Other information SECTION 10: Stability and reactivity 10.1. Reactivity Not reactive. 10.2. Chemical stability Stable under normal conditions. _____________________________________________________________________________________ Boiling point/boiling range No information available Water Solubility Negligible Odor Threshold No information available Solubility(ies) Soluble in Solvent Not applicable Flash Point Partition Coefficient (n-octanol/water) > 3 Appearance Autoignition Temperature No information available Clear Decomposition Temperature No information available Flash point COC Kinematic Viscosity 208 ?C LSC TRANSMISSION FLUID 12-301 Viscosity at 40?C Typical 28.5 mm?/s ISO 2592 ISO 3104 Viscosity at 100?C Typical 6.0 mm?/s Property ISO 3104 Flash point PM Dynamic viscosity No information available Values Explosive Properties Not applicable Not applicable Oxidizing Properties Odor Not applicable Evaporation Rate 5HPDUNV????0HWKRG?? Not applicable Molecular Weight Oil No information available Flammability (solid, gas) VOC Content(%) No information available Density 866 kg/m? Not applicable ISO 12185 pH Bulk density Flammability Limits in Air No information available Research Octane Number Not applicable Revision date 10-Apr-2015 Sulphur Content Not applicable Upper Flammability limits Not applicable Not applicable Color Lower Flammability Limit Melting Point/Freezing Point Not applicable Vapor pressure @20?C (kPa) < 0.01 Brown Not applicable Vapor Density Not applicable Page 5 / 10 Relative Density _____________________________________________________________________________________ 10.3. Possibility of hazardous reactions Possibility of hazardous reactions None under normal processing. 10.4. Conditions to avoid Heat, flames and sparks. 10.5. Incompatible materials Strong oxidizing agents. 10.6. Hazardous decomposition products None under normal use conditions. Thermal decomposition can lead to release of irritating and toxic gases and vapors. Carbon monoxide. SECTION 11: Toxicological information 11.1. Information on toxicological effects Product Information Product does not present an acute toxicity hazard based on known or supplied information. Used product can contain harmful contaminants. Acute toxicity Inhalation Inhalation of vapors in high concentration may cause irritation of respiratory system. Eye Contact Contact with eyes may cause irritation. Skin Contact Prolonged contact may cause redness and irritation. May cause skin irritation and/or dermatitis. Product that under high pressure has been forced under the skin, may causae serious cell damage/death under the skin. Ingestion Potential for aspiration if swallowed. Aspiration may cause pulmonary edema and pneumonitis. Skin corrosion/irritation None known. Serious eye damage/eye irritation None known. Sensitization None known. Germ cell mutagenicity None known. Carcinogenicity None known. Reproductive Toxicity None known. Developmental toxicity None known. Teratogenicity None known. STOT - single exposure None known. _____________________________________________________________________________________ Revision date 10-Apr-2015 Page 6 / 10 LSC TRANSMISSION FLUID 12-301 _____________________________________________________________________________________ STOT - repeated exposure None known. Neurological effects None known. Target organ effects None known. Aspiration hazard None known. SECTION 12: Ecological information 12.1. Toxicity Not harmful to aquatic organisms. Expected LC/EC 50 value >100 mg/l Chemical name Algae/aquatic plants Fish Crustacea zinc bis[O,O-bis(2-ethylhexyl)] bis(dithiophosphate) 1.0 - 5.0: 96 h Pseudokirchneriella subcapitata mg/L EC50 1.0 - 5.0: 96 h Pimephales promelas mg/L LC50 static 10.0 - 35.0: 96 h Pimephales promelas mg/L LC50 semi-static 1 - 1.5: 48 h Daphnia magna mg/L EC50 12.2. Persistence and degradability Potentially degradable, but will persist in the environment for long periods. 12.3. Bioaccumulative potential Contain components with potential to bioaccumulate (logPow >3). 12.4. Mobility in soil Mobility in soil After release, adsorbs onto soil. 12.5. Results of PBT and vPvB assessment This product is not, or does not contain, a substance that is a PBT or a vBvP. 12.6. Other adverse effects An oilfilm may cause physical damage to organisms and disturb the transportation of oxygen in the intermediate zone between air/water or air/soil SECTION 13: Disposal considerations 13.1. Waste treatment methods Waste from Residues / Unused Products Disposal should be in accordance with applicable regional, national and local laws and regulations. _____________________________________________________________________________________ LSC TRANSMISSION FLUID 12-301 Page 7 / 10 Revision date 10-Apr-2015 _____________________________________________________________________________________ Other information Provisions for waste transmitters: Different types of hazardous waste shall not be mixed with each other. Wastes can be mixed if the purpose is to improve safety during disposal or recycling or otherwise is done in a manner acceptable to protect the environment. Waste may be transported professionally only by those who have special permission. Solvent and oil waste under certain given amounts may be transported without special permission, after notification to the County Board. Contact the County Board for further information. Discharge Instructions: Packs marked with a skull or environmental hazard symbol and risk phrase 50/53 should always be disposed of as hazardous waste. Other packs should be emptied well before they can be recycled or reconditioned. The contents may need to be disposed of as hazardous waste. Draining is best carried out at room temperature. The pack is placed upside down inclined somewhat, about 10 degrees, the runoff should be in such a way that the lowest point of the pack is the exit. Residual content should be collected and added to the process there the product is used. For steel drums especially the runoff must be at room temperature (min 15 ? C). Wait until the pack is drip dry. Do not reseal the packs after runoff. Note in particular the risks involved when emptying containers containing flammable liquids. Emptied packages should be ventilated in a safe place away from sparks and fire. Residues may cause an explosion. Do not puncture, cut or weld in uncleaned packages, containers or barrels. If possible, packs contained water-soluble product should be rinsed thoroughly (3 times) before emptying. The rinse water should, if possible, be used in the process there the product is used. Classification of wastes: Waste transmitters is required to classify the waste. All waste is identified by a six digit EWC code. The codes are listed in the Waste Regulation. The codes for oil waste are based on usage and the base oil. Information about the intended use is given in the safety data sheet, section 1. Oil waste is always hazardous waste. Examples of EWC codes for oil waste:120107: mineral-based machining oils free of halogens130111: Synthetic Hydraulic Oils130105: Non-chlorinated emulsions130208: other engine, gear and lubricating oils Waste codes should be assigned by the user based on the application for which the product was used. SECTION 14: Transport information IMDG 14.1 UN/ID no Not regulated 14.2 Proper Shipping Name Not regulated 14.3 Hazard Class Not regulated 14.4 Packing group Not regulated 14.5 Marine pollutant Not applicable 14.6 Special Provisions None 14.7 Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code No information available RID 14.1 UN/ID no Not regulated 14.2 Proper Shipping Name Not regulated 14.3 Hazard Class Not regulated 14.4 Packing group Not regulated 14.5 environmental hazard Not applicable 14.6 Special Provisions None ADR 14.1 UN/ID no Not regulated _____________________________________________________________________________________ LSC TRANSMISSION FLUID 12-301 Revision date 10-Apr-2015 Page 8 / 10 _____________________________________________________________________________________ 14.2 Proper Shipping Name Not regulated 14.3 Hazard Class Not regulated 14.4 Packing group Not regulated 14.5 environmental hazard Not applicable 14.6 Special Provisions None ICAO (air) 14.1 UN/ID no Not regulated 14.2 Proper Shipping Name Not regulated 14.3 Hazard Class Not regulated 14.4 Packing group Not regulated 14.5 environmental hazard Not applicable 14.6 Special Provisions None IATA 14.1 UN/ID no Not regulated 14.2 Proper Shipping Name Not regulated 14.3 Hazard Class Not regulated 14.4 Packing group Not regulated 14.5 environmental hazard Not applicable 14.6 Special Provisions None SECTION 15: Regulatory information 15.1. Safety, health and environmental regulations/legislation specific for the substance or mixture National regulations This safety data sheet is created with use of legislation & regulation valid for the European Union, for example consolidated versions of REACh,1907/2006; CLP, 1272/2008; DPD 1999/45 and national legislation. Danish PR number: - International Inventories TSCA Complies EINECS/ELINCS Complies DSL/NDSL Complies PICCS Complies ENCS Complies IECSC Complies AICS Complies KECL Complies Legend EINECS/ELINCS - European Inventory of Existing Chemical Substances/European List of Notified Chemical Substances DSL/NDSL - Canadian Domestic Substances List/Non-Domestic Substances List PICCS - Philippines Inventory of Chemicals and Chemical Substances ENCS - Japan Existing and New Chemical Substances IECSC - China Inventory of Existing Chemical Substances AICS - Australian Inventory of Chemical Substances KECL - Korean Existing and Evaluated Chemical Substances 15.2. Chemical safety assessment No information available SECTION 16: Other information _____________________________________________________________________________________ Revision date 10-Apr-2015 Page 9 / 10 LSC TRANSMISSION FLUID 12-301 _____________________________________________________________________________________ Full text of R-phrases referred to under sections 2 and 3 R41 - Risk of serious damage to eyes R43 - May cause sensitization by skin contact R51/53 - Toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment Full text of H-Statements referred to under section 3 H411 - Toxic to aquatic life with long lasting effects H318 - Causes serious eye damage H317 - May cause an allergic skin reaction Key or legend to abbreviations and acronyms used in the safety data sheet vBvP = Very Bioaccumulative and very Pollutant. PBT = Persistant Bioccumulative Toxic chemical REACh = Research Evaluation Authorization and Restriction of Chemicals CLP = Classification, Labelling and Packaging DPD = Dangerous Preparations Directive VOC=Volatile Organic Compound Issue Date 12-Apr-2013 Revision date 10-Apr-2015 Revision Note Indication of changes *** , if applicable. This material safety data sheet complies with the requirements of Regulation (EC) No. 1907/2006 End of Safety Data Sheet _____________________________________________________________________________________ Page 10 / 10 LSC TRANSMISSION FLUID 12-301 Revision date 10-Apr-2015