SDS Repository

sds

Collection
AC Delco
Description
 
Tags
Search Tag
Filename
10-9030_msds.pdf
Source
 
Full Text
Material Safety Data Sheet DEXRON ? VI ATF 000003000398 Version 2.0 Revision Date 2015/01/26 Print Date 2015/03/12 Internet: lubricants.petro-canada.ca/msds Page: 1 / 9 Petro-Canada is a Suncor Energy business. TM Trademark of Suncor Energy Inc. Used under licence. SECTION 1. PRODUCT AND COMPANY IDENTIFICATION Product name : DEXRON ? VI ATF Synonyms : RDL-3434, DEXRON VI Product code : GMDEX6IBC, GMDEX6DRM, GMDEX6CQT, GMDEX6C4U, GMDEX6BLK Manufacturer or supplier's details Petro-Canada America Lubricants Inc. 115N Oak Park Avenue #1C Oak Park IL 60301-1366 United States Emergency telephone number Suncor Energy: +1 403-296-3000; Poison Control Centre: Consult local telephone directory for emergency number(s). Recommended use of the chemical and restrictions on use Recommended use : Automatic Transmission Fluid for use in General Motors vehicles, requiring GM Material Specification # 9986153. Prepared by : Product Safety: +1 905-804-4752 SECTION 2. HAZARDS IDENTIFICATION Emergency Overview Appearance viscous liquid Colour red Odour Mild petroleum oil like. GHS Classification Not a hazardous substance or mixture. GHS Label element Not a hazardous substance or mixture. Potential Health Effects Primary Routes of Entry : Eye contact Ingestion Inhalation Skin contact Aggravated Medical Condition : None known. 10-9035, 88861046, 10-9029, 88861037, 10-9030, 88861954 - ACDelco DEXRON?- VI Automatic Transmission Fluid Material Safety Data Sheet DEXRON ? VI ATF 000003000398 Version 2.0 Revision Date 2015/01/26 Print Date 2015/03/12 Internet: lubricants.petro-canada.ca/msds Page: 2 / 9 Petro-Canada is a Suncor Energy business. TM Trademark of Suncor Energy Inc. Used under licence. Carcinogenicity: IARC No component of this product present at levels greater than or equal to 0.1% is identified as probable, possible or confirmed human carcinogen by IARC. ACGIH No component of this product present at levels greater than or equal to 0.1% is identified as a carcinogen or potential carcinogen by ACGIH. OSHA No component of this product present at levels greater than or equal to 0.1% is identified as a carcinogen or potential carcinogen by OSHA. NTP No component of this product present at levels greater than or equal to 0.1% is identified as a known or anticipated carcinogen by NTP. SECTION 3. COMPOSITION/INFORMATION ON INGREDIENTS Pure substance/mixture : Mixture Hazardous components Chemical Name CAS-No. Concentration (%) lubricating oils (petroleum), C15-30, hydrotreated neutral oil-based 72623-86-0 50 - 70 % Methacrylate copolymers 1 - 5 % Alkoxylated long-chain alkyl amine 0.1 - 1 % SECTION 4. FIRST AID MEASURES If inhaled : Move to fresh air. Artificial respiration and/or oxygen may be necessary. Seek medical advice. In case of skin contact : In case of contact, immediately flush eyes or skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Wash skin thoroughly with soap and water or use recognized skin cleanser. Wash clothing before reuse. Seek medical advice. In case of eye contact : Remove contact lenses. Rinse immediately with plenty of water, also under the eyelids, for at least 15 minutes. Obtain medical attention. If swallowed : Rinse mouth with water. Material Safety Data Sheet DEXRON ? VI ATF 000003000398 Version 2.0 Revision Date 2015/01/26 Print Date 2015/03/12 Internet: lubricants.petro-canada.ca/msds Page: 3 / 9 Petro-Canada is a Suncor Energy business. TM Trademark of Suncor Energy Inc. Used under licence. DO NOT induce vomiting unless directed to do so by a physician or poison control center. Never give anything by mouth to an unconscious person. Seek medical advice. Most important symptoms and effects, both acute and delayed : First aider needs to protect himself. SECTION 5. FIREFIGHTING MEASURES Suitable extinguishing media : Use extinguishing measures that are appropriate to local circumstances and the surrounding environment. Unsuitable extinguishing media : No information available. Specific hazards during firefighting : Cool closed containers exposed to fire with water spray. Hazardous combustion products : Carbon oxides (CO, CO2), nitrogen oxides (NOx), smoke and irritating vapours as products of incomplete combustion. Further information : Prevent fire extinguishing water from contaminating surface water or the ground water system. SECTION 6. ACCIDENTAL RELEASE MEASURES Personal precautions, protective equipment and emergency procedures : Use personal protective equipment. Ensure adequate ventilation. Evacuate personnel to safe areas. Material can create slippery conditions. Environmental precautions : If the product contaminates rivers and lakes or drains inform respective authorities. Methods and materials for containment and cleaning up : Prevent further leakage or spillage if safe to do so. Remove all sources of ignition. Soak up with inert absorbent material. Non-sparking tools should be used. Ensure adequate ventilation. Contact the proper local authorities. SECTION 7. HANDLING AND STORAGE Advice on safe handling : For personal protection see section 8. Smoking, eating and drinking should be prohibited in the application area. In case of insufficient ventilation, wear suitable respiratory equipment. Avoid contact with skin, eyes and clothing. Do not ingest. Material Safety Data Sheet DEXRON ? VI ATF 000003000398 Version 2.0 Revision Date 2015/01/26 Print Date 2015/03/12 Internet: lubricants.petro-canada.ca/msds Page: 4 / 9 Petro-Canada is a Suncor Energy business. TM Trademark of Suncor Energy Inc. Used under licence. Keep away from heat and sources of ignition. Keep container closed when not in use. Conditions for safe storage : Store in original container. Containers which are opened must be carefully resealed and kept upright to prevent leakage. Keep in a dry, cool and well-ventilated place. Keep in properly labelled containers. To maintain product quality, do not store in heat or direct sunlight. SECTION 8. EXPOSURE CONTROLS/PERSONAL PROTECTION Components with workplace control parameters Contains no substances with occupational exposure limit values. Engineering measures : No special ventilation requirements. Good general ventilation should be sufficient to control worker exposure to airborne contaminants. Personal protective equipment Respiratory protection : Use respiratory protection unless adequate local exhaust ventilation is provided or exposure assessment demonstrates that exposures are within recommended exposure guidelines. Respirator selection must be based on known or anticipated exposure levels, the hazards of the product and the safe working limits of the selected respirator. Filter type : organic vapour filter Hand protection Material : neoprene, nitrile, polyvinyl alcohol (PVA), Viton(R). Remarks : Chemical-resistant, impervious gloves complying with an approved standard should be worn at all times when handling chemical products if a risk assessment indicates this is necessary. Eye protection : Wear face-shield and protective suit for abnormal processing problems. Skin and body protection : Choose body protection in relation to its type, to the concentration and amount of dangerous substances, and to the specific work-place. Protective measures : Wash hands and face before breaks and immediately after handling the product. Wash contaminated clothing before re-use. Ensure that eyewash station and safety shower are proximal to the work-station location. Hygiene measures : Remove and wash contaminated clothing and gloves, including the inside, before re-use. Wash face, hands and any exposed skin thoroughly after Material Safety Data Sheet DEXRON ? VI ATF 000003000398 Version 2.0 Revision Date 2015/01/26 Print Date 2015/03/12 Internet: lubricants.petro-canada.ca/msds Page: 5 / 9 Petro-Canada is a Suncor Energy business. TM Trademark of Suncor Energy Inc. Used under licence. handling. SECTION 9. PHYSICAL AND CHEMICAL PROPERTIES Appearance : viscous liquid Colour : red Odour : Mild petroleum oil like. Odour Threshold : No data available pH : No data available Pour point : -54 ?C (-65 ?F) Boiling point/boiling range : No data available Flash point : 206 ?C (403 ?F) Method: Cleveland open cup Fire Point : 230 ?C (446 ?F) Auto-Ignition Temperature : No data available Evaporation rate : No data available Flammability : Low fire hazard. This material must be heated before ignition will occur. Upper explosion limit : No data available Lower explosion limit : No data available Vapour pressure : No data available Density : 0.846 kg/l (15 ?C / 59 ?F) Solubility(ies) Water solubility : insoluble Partition coefficient: n- octanol/water : No data available Viscosity Viscosity, kinematic : 29.8 cSt (40 ?C / 104 ?F) 6.0 cSt (100 ?C / 212 ?F) Explosive properties : Do not pressurise, cut, weld, braze, solder, drill, grind or expose containers to heat or sources of ignition. SECTION 10. STABILITY AND REACTIVITY Possibility of hazardous : Hazardous polymerisation does not occur. Material Safety Data Sheet DEXRON ? VI ATF 000003000398 Version 2.0 Revision Date 2015/01/26 Print Date 2015/03/12 Internet: lubricants.petro-canada.ca/msds Page: 6 / 9 Petro-Canada is a Suncor Energy business. TM Trademark of Suncor Energy Inc. Used under licence. reactions Stable under normal conditions. Conditions to avoid : No data available Incompatible materials : Reactive with oxidising agents, acids and reducing agents. Hazardous decomposition products : May release COx, NOx, smoke and irritating vapours when heated to decomposition. SECTION 11. TOXICOLOGICAL INFORMATION Information on likely routes of exposure Eye contact Ingestion Inhalation Skin contact Acute toxicity Product: Acute oral toxicity Remarks: No data available Acute inhalation toxicity Remarks: No data available Acute dermal toxicity Remarks: No data available Components: lubricating oils (petroleum), C15-30, hydrotreated neutral oil-based: Acute oral toxicity LD50 (Rat): > 5,000 mg/kg Acute inhalation toxicity LC50 (Rat): > 5.2 mg/l Exposure time: 4 h Test atmosphere: dust/mist Acute dermal toxicity LD50 (Rabbit): > 2,000 mg/kg Skin corrosion/irritation Product: Remarks: No data available Serious eye damage/eye irritation Product: Remarks: No data available Respiratory or skin sensitisation No data available Germ cell mutagenicity No data available Carcinogenicity Material Safety Data Sheet DEXRON ? VI ATF 000003000398 Version 2.0 Revision Date 2015/01/26 Print Date 2015/03/12 Internet: lubricants.petro-canada.ca/msds Page: 7 / 9 Petro-Canada is a Suncor Energy business. TM Trademark of Suncor Energy Inc. Used under licence. No data available Reproductive toxicity No data available STOT - single exposure No data available STOT - repeated exposure No data available SECTION 12. ECOLOGICAL INFORMATION Ecotoxicity Product: Toxicity to fish : Remarks: No data available Toxicity to daphnia and other aquatic invertebrates : Remarks: No data available Toxicity to algae : Remarks: No data available Toxicity to bacteria : Remarks: No data available Persistence and degradability Product: Biodegradability : Remarks: No data available Bioaccumulative potential No data available Mobility in soil No data available Other adverse effects No data available SECTION 13. DISPOSAL CONSIDERATIONS Disposal methods Waste from residues : The product should not be allowed to enter drains, water courses or the soil. Offer surplus and non-recyclable solutions to a licensed disposal company. Waste must be classified and labelled prior to recycling or disposal. Send to a licensed waste management company. Dispose of as hazardous waste in compliance with local and national regulations. Material Safety Data Sheet DEXRON ? VI ATF 000003000398 Version 2.0 Revision Date 2015/01/26 Print Date 2015/03/12 Internet: lubricants.petro-canada.ca/msds Page: 8 / 9 Petro-Canada is a Suncor Energy business. TM Trademark of Suncor Energy Inc. Used under licence. Dispose of product residue in accordance with the instructions of the person responsible for waste disposal. SECTION 14. TRANSPORT INFORMATION International Regulation IATA-DGR Not regulated as a dangerous good IMDG-Code Not regulated as a dangerous good Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code Not applicable for product as supplied. 49 CFR Not regulated as a dangerous good TDG Not regulated as a dangerous good Special precautions for user Not applicable SECTION 15. REGULATORY INFORMATION OSHA Hazards : No OSHA Hazards The components of this product are reported in the following inventories: DSL On the inventory, or in compliance with the inventory TSCA All chemical substances in this product are either listed on the TSCA Inventory or are in compliance with a TSCA Inventory exemption. EINECS On the inventory, or in compliance with the inventory IECSC On the inventory, or in compliance with the inventory SECTION 16. OTHER INFORMATION Material Safety Data Sheet DEXRON ? VI ATF 000003000398 Version 2.0 Revision Date 2015/01/26 Print Date 2015/03/12 Internet: lubricants.petro-canada.ca/msds Page: 9 / 9 Petro-Canada is a Suncor Energy business. TM Trademark of Suncor Energy Inc. Used under licence. Further information NFPA: HMIS III: For Copy of (M)SDS : Internet: lubricants.petro-canada.ca/msds United States, telephone: 1-800-268-5850; fax: 1-800-201- 6285 For Product Safety Information: 1 905-804-4752 Prepared by : Product Safety: +1 905-804-4752 The information provided in this Safety Data Sheet is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guidance for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process, unless specified in the text. Flammability H ea lth Instability 1 1 0 Special hazard. FLAMMABILITY PHYSICAL HAZARD HEALTH 1 0 1 0 = not significant, 1 =Slight, 2 = Moderate, 3 = High 4 = Extreme, * = Chronic PERSONAL PROTECTION B