SDS Repository

sds

Collection
CRC
Description
 
Tags
Search Tag
Filename
05007_Power_Lube_Multi-Purpose_Lubricant.pdf
Source
 
Full Text
SAFETY DATA SHEET 1. Identification Product identifier Power Lube? Multi-Purpose Lubricant Other means of identification Product code 05007, 05009, 05011 Recommended use Multi-purpose lubricant Recommended restrictions None known. Manufacturer/Importer/Supplier/Distributor information Manufactured or sold by: Company name CRC Industries, Inc. Address 885 Louis Dr. Warminster, PA 18974 US Telephone General Information 215-674-4300 Technical Assistance 800-521-3168 Customer Service 800-272-4620 24-Hour Emergency 800-424-9300 (US) (CHEMTREC) 703-527-3887 (International) Website www.crcindustries.com 2. Hazard(s) identification Category 4Flammable liquidsPhysical hazards Category 2Skin corrosion/irritationHealth hazards Category 3 narcotic effectsSpecific target organ toxicity, single exposure Category 2Specific target organ toxicity, repeated exposure Category 1Aspiration hazard Category 2Hazardous to the aquatic environment, acute hazard Environmental hazards Not classified.OSHA defined hazards Label elements Signal word Danger Hazard statement Combustible liquid. May be fatal if swallowed and enters airways. Causes skin irritation. May cause drowsiness or dizziness. May cause damage to organs through prolonged or repeated exposure. Toxic to aquatic life. Precautionary statement Prevention Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Use with adequate ventilation. Open doors and windows or use other means to ensure a fresh air supply during use and while product is drying. If you experience any symptoms listed on this label, increase ventilation or leave the area. Do not breathe mist or vapor. Wear protective gloves/eye protection/face protection. Wash hands thoroughly after handling. Avoid release to the environment. Response If swallowed: Immediately call a poison center/doctor. Do NOT induce vomiting. If on skin: Wash with plenty of water. If skin irritation occurs: Get medical attention. Take off contaminated clothing and wash before reuse. If inhaled: Remove person to fresh air and keep comfortable for breathing. Call a poison center/doctor if you feel unwell. In case of fire: Do not use water jet as an extinguisher, as this will spread the fire. Storage Store in a well-ventilated place. Keep container tightly closed. Keep cool. Store locked up. Disposal Dispose of contents/container in accordance with local/regional/national regulations. Hazard(s) not otherwise classified (HNOC) None known. 1 / 8 Material name: Power Lube? Multi-Purpose Lubricant 1376 Version #: 01 Issue date: 10-29-2013 SDS US Supplemental information 33.07% of the mixture consists of component(s) of unknown acute hazards to the aquatic environment. 3. Composition/information on ingredients Mixtures CAS number %Chemical name Common name and synonyms 64742-47-8Distillates (petroleum), Hydrotreated Light 60 - 70 64741-88-4Distillates (petroleum), Solvent-refined Heavy Paraffinic 10 - 20 123-95-5n-Butyl stearate 3 - 5 61788-89-4Fatty Acids, C18-unsatd., Dimers 1 - 3 119-36-8Methyl salicylate 1 - 3 8009-03-8Petrolatum 1 - 3 Specific chemical identity and/or percentage of composition has been withheld as a trade secret. 4. First-aid measures Inhalation Remove victim to fresh air and keep at rest in a position comfortable for breathing. Call a POISON CENTER or doctor/physician if you feel unwell. Skin contact Rinse skin with water/shower. If skin irritation occurs: Get medical advice/attention. Take off contaminated clothing and wash before reuse. Eye contact Rinse with water. Get medical attention if irritation develops and persists. Ingestion Call a physician or poison control center immediately. Rinse mouth. Do not induce vomiting. If vomiting occurs, keep head low so that stomach content doesn't get into the lungs. Aspiration may cause pulmonary edema and pneumonitis. Most important symptoms/effects, acute and delayed Direct contact with eyes may cause temporary irritation. Skin irritation. Vapors have a narcotic effect and may cause headache, fatigue, dizziness and nausea. May cause redness and pain. Prolonged exposure may cause chronic effects. Indication of immediate medical attention and special treatment needed Provide general supportive measures and treat symptomatically. Keep victim under observation. Symptoms may be delayed. General information Ensure that medical personnel are aware of the material(s) involved, and take precautions to protect themselves. 5. Fire-fighting measures Suitable extinguishing media Alcohol resistant foam. Water spray. Water fog. Dry chemical powder. Dry chemicals. Carbon dioxide (CO2). Unsuitable extinguishing media Water. Do not use water jet as an extinguisher, as this will spread the fire. Specific hazards arising from the chemical The product is combustible, and heating may generate vapors which may form explosive vapor/air mixtures. During fire, gases hazardous to health may be formed. Special protective equipment and precautions for firefighters Self-contained breathing apparatus and full protective clothing must be worn in case of fire. Fire-fighting equipment/instructions In case of fire and/or explosion do not breathe fumes. Move containers from fire area if you can do so without risk. Cool containers exposed to heat with water spray and remove container, if no risk is involved. General fire hazards Combustible liquid. 6. Accidental release measures Personal precautions, protective equipment and emergency procedures Keep unnecessary personnel away. Keep people away from and upwind of spill/leak. Keep out of low areas. Eliminate all ignition sources (no smoking, flares, sparks, or flames in immediate area). Wear appropriate protective equipment and clothing during clean-up. Do not breathe mist or vapor. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Ensure adequate ventilation. Local authorities should be advised if significant spillages cannot be contained. For personal protection, see section 8 of the SDS. 2 / 8 Material name: Power Lube? Multi-Purpose Lubricant 1376 Version #: 01 Issue date: 10-29-2013 SDS US Methods and materials for containment and cleaning up Eliminate all ignition sources (no smoking, flares, sparks, or flames in immediate area). Keep combustibles (wood, paper, oil, etc.) away from spilled material. Large Spills: Stop the flow of material, if this is without risk. Dike the spilled material, where this is possible. Cover with plastic sheet to prevent spreading. Use a non-combustible material like vermiculite, sand or earth to soak up the product and place into a container for later disposal. Use water spray to reduce vapors or divert vapor cloud drift. Prevent entry into waterways, sewer, basements or confined areas. Following product recovery, flush area with water. Small Spills: Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination. Never return spills to original containers for re-use. For waste disposal, see section 13 of the SDS. Environmental precautions Avoid release to the environment. Contact local authorities in case of spillage to drain/aquatic environment. Prevent further leakage or spillage if safe to do so. Do not contaminate water. Avoid discharge into drains, water courses or onto the ground. 7. Handling and storage Precautions for safe handling Keep away from open flames, hot surfaces and sources of ignition. When using do not smoke. Do not breathe mist or vapor. Avoid contact with skin. Avoid contact with eyes. Avoid prolonged exposure. Avoid contact with clothing. Use only in well-ventilated areas. Wear appropriate personal protective equipment. Observe good industrial hygiene practices. Wash hands thoroughly after handling. Avoid release to the environment. Do not empty into drains. For product usage instructions, please see the product label. Conditions for safe storage, including any incompatibilities Keep away from heat and sources of ignition. Store in original tightly closed container. Store in a cool, dry place out of direct sunlight. Store in a well-ventilated place. Store away from incompatible materials (see Section 10 of the SDS). Keep in an area equipped with sprinklers. 8. Exposure controls/personal protection Occupational exposure limits U.S. - OSHA ValueComponents FormType TWA 5 mg/m3 RespirableFatty Acids, C18-unsatd., Dimers (CAS 61788-89-4) US. OSHA Table Z-1 Limits for Air Contaminants (29 CFR 1910.1000) ValueComponents FormType PEL 5 mg/m3 Mist.Distillates (petroleum), Solvent-refined Heavy Paraffinic (CAS 64741-88-4) 2000 mg/m3 500 ppm PEL 5 mg/m3 Mist.Petrolatum (CAS 8009-03-8) ACGIH ValueComponents FormType STEL 10 mg/m3 RespirableFatty Acids, C18-unsatd., Dimers (CAS 61788-89-4) TWA 5 mg/m3 Respirable US. ACGIH Threshold Limit Values ValueComponents FormType TWA 5 mg/m3 Inhalable fraction.Distillates (petroleum), Solvent-refined Heavy Paraffinic (CAS 64741-88-4) TWA 10 mg/m3n-Butyl stearate (CAS 123-95-5) TWA 5 mg/m3 Inhalable fraction.Petrolatum (CAS 8009-03-8) US. NIOSH: Pocket Guide to Chemical Hazards ValueComponents FormType TWA 100 mg/m3Distillates (petroleum), Hydrotreated Light (CAS 64742-47-8) 3 / 8 Material name: Power Lube? Multi-Purpose Lubricant 1376 Version #: 01 Issue date: 10-29-2013 SDS US US. NIOSH: Pocket Guide to Chemical Hazards ValueComponents FormType STEL 10 mg/m3 Mist.Distillates (petroleum), Solvent-refined Heavy Paraffinic (CAS 64741-88-4) TWA 5 mg/m3 Mist. STEL 10 mg/m3 Mist.Petrolatum (CAS 8009-03-8) TWA 5 mg/m3 Mist. Biological limit values No biological exposure limits noted for the ingredient(s). Appropriate engineering controls Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level. Eye wash facilities and emergency shower must be available when handling this product. Individual protection measures, such as personal protective equipment Eye/face protection Wear safety glasses with side shields (or goggles). Skin protection Hand protection Wear protective gloves such as neoprene or nitrile. Other Wear appropriate chemical resistant clothing. Respiratory protection If engineering controls do not maintain airborne concentrations below recommended exposure limits (where applicable) or to an acceptable level (in countries where exposure limits have not been established), an approved respirator must be worn. Wear positive pressure self-contained breathing apparatus (SCBA). Air monitoring is needed to determine actual employee exposure levels. Thermal hazards Wear appropriate thermal protective clothing, when necessary. General hygiene considerations When using, do not eat, drink or smoke. Always observe good personal hygiene measures, such as washing after handling the material and before eating, drinking, and/or smoking. Routinely wash work clothing and protective equipment to remove contaminants. 9. Physical and chemical properties Appearance Physical state Liquid. Form Liquid. Color Amber. Odor Mint. Odor threshold Not available. pH Not available. Melting point/freezing point -72.4 ?F (-58 ?C) estimated Initial boiling point and boiling range 212 ?F (100 ?C) estimated Flash point 196 ?F (91.1 ?C) Tag Closed Cup Evaporation rate Not available. Flammability (solid, gas) Not available. Upper/lower flammability or explosive limits Flammability limit - lower (%) 0.6 % estimated Flammability limit - upper (%) 5.5 % estimated Vapor pressure 0.2 hPa estimated Vapor density > 1 (air = 1) Relative density 0.83 Solubility (water) Not available. Partition coefficient (n-octanol/water) Not available. Auto-ignition temperature 456.8 ?F (236 ?C) estimated Decomposition temperature Not available. Viscosity (kinematic) Not available. 4 / 8 Material name: Power Lube? Multi-Purpose Lubricant 1376 Version #: 01 Issue date: 10-29-2013 SDS US Percent volatile 90.9 % estimated 10. Stability and reactivity Reactivity The product is stable and non-reactive under normal conditions of use, storage and transport. Chemical stability Material is stable under normal conditions. Possibility of hazardous reactions No dangerous reaction known under conditions of normal use. Conditions to avoid Avoid heat, sparks, open flames and other ignition sources. Avoid temperatures exceeding the flash point. Contact with incompatible materials. Incompatible materials Strong oxidizing agents. Hazardous decomposition products No hazardous decomposition products are known. 11. Toxicological information Information on likely routes of exposure Ingestion May be fatal if swallowed and enters airways. Inhalation Vapors have a narcotic effect and may cause headache, fatigue, dizziness and nausea. Prolonged inhalation may be harmful. May cause damage to organs by inhalation. Skin contact Causes skin irritation. Eye contact Direct contact with eyes may cause temporary irritation. Symptoms related to the physical, chemical and toxicological characteristics Skin irritation. May cause redness and pain. Symptoms of overexposure may be headache, dizziness, tiredness, nausea and vomiting. Information on toxicological effects Acute toxicity May be fatal if swallowed and enters airways. Narcotic effects. Test ResultsProduct Species Power Lube? Multi-Purpose Lubricant LD50 Rabbit Dermal Acute 2775.3591 mg/kg estimated LC50 Rat Inhalation 189.8629 mg/l estimated LD50 Rat Oral 5986.6416 mg/kg estimated LD50 Rat Oral Subchronic 760.4854 g/kg, 14 days estimated * Estimates for product may be based on additional component data not shown. Skin corrosion/irritation Causes skin irritation. Serious eye damage/eye irritation Direct contact with eyes may cause temporary irritation. Respiratory sensitization Not available. Skin sensitization This product is not expected to cause skin sensitization. Germ cell mutagenicity No data available to indicate product or any components present at greater than 0.1% are mutagenic or genotoxic. Carcinogenicity This product is not considered to be a carcinogen by IARC, ACGIH, NTP, or OSHA. Reproductive toxicity This product is not expected to cause reproductive or developmental effects. Specific target organ toxicity - single exposure Narcotic effects. Specific target organ toxicity - repeated exposure May cause damage to organs through prolonged or repeated exposure. Aspiration hazard May be fatal if swallowed and enters airways. Chronic effects Prolonged inhalation may be harmful. May cause damage to organs through prolonged or repeated exposure. 12. Ecological information Ecotoxicity Toxic to aquatic life. 5 / 8 Material name: Power Lube? Multi-Purpose Lubricant 1376 Version #: 01 Issue date: 10-29-2013 SDS US Product Test ResultsSpecies Power Lube? Multi-Purpose Lubricant Acute LC50Fish 4814.8149 ppm, 96 hours estimatedFish Components Test ResultsSpecies Distillates (petroleum), Hydrotreated Light (CAS 64742-47-8) Aquatic Acute LC50Fish 2.2 mg/l, 96 hoursBluegill (Lepomis macrochirus) Fatty Acids, C18-unsatd., Dimers (CAS 61788-89-4) Acute NOELCrustacea 1000 mg/l, 48 hours loading rate WAFDaphnia * Estimates for product may be based on additional component data not shown. NOELFish 1000 mg/l, 96 hours loading rate WAFFish Persistence and degradability No data is available on the degradability of this product. Bioaccumulative potential No data available. Partition coefficient n-octanol / water (log Kow) Fatty Acids, C18-unsatd., Dimers 1 - 2.5, logKow Methyl salicylate 2.55 Mobility in soil No data available. Other adverse effects No other adverse environmental effects (e.g. ozone depletion, photochemical ozone creation potential, endocrine disruption, global warming potential) are expected from this component. 13. Disposal considerations Disposal of waste from residues / unused products This product is not a RCRA hazardous waste (See 40 CFR Part 261.20 ? 261.33). Empty containers may be recycled. Do not allow this material to drain into sewers/water supplies. Do not contaminate ponds, waterways or ditches with chemical or used container. Dispose of contents/container in accordance with local/regional/national regulations. Hazardous waste code Not regulated. Contaminated packaging Empty containers should be taken to an approved waste handling site for recycling or disposal. Since emptied containers may retain product residue, follow label warnings even after container is emptied. 14. Transport information DOT Not regulated as dangerous goods. IATA Not regulated as dangerous goods. IMDG Not regulated as dangerous goods. 15. Regulatory information US federal regulations This product is a "Hazardous Chemical" as defined by the OSHA Hazard Communication Standard, 29 CFR 1910.1200. TSCA Section 12(b) Export Notification (40 CFR 707, Subpt. D) Not regulated. SARA 304 Emergency release notification Not regulated. US. OSHA Specifically Regulated Substances (29 CFR 1910.1001-1050) Not listed. US EPCRA (SARA Title III) Section 313 - Toxic Chemical: Listed substance Not listed. CERCLA Hazardous Substance List (40 CFR 302.4) Not listed. CERCLA Hazardous Substances: Reportable quantity Not listed. Spills or releases resulting in the loss of any ingredient at or above its RQ require immediate notification to the National Response Center (800-424-8802) and to your Local Emergency Planning Committee. 6 / 8 Material name: Power Lube? Multi-Purpose Lubricant 1376 Version #: 01 Issue date: 10-29-2013 SDS US Clean Air Act (CAA) Section 112 Hazardous Air Pollutants (HAPs) List Not regulated. Clean Air Act (CAA) Section 112(r) Accidental Release Prevention (40 CFR 68.130) Not regulated. Safe Drinking Water Act (SDWA) Not regulated. Food and Drug Administration (FDA) Not regulated. Superfund Amendments and Reauthorization Act of 1986 (SARA) Section 311/312 Hazard categories Immediate Hazard - Yes Delayed Hazard - Yes Fire Hazard - Yes Pressure Hazard - No Reactivity Hazard - No SARA 302 Extremely hazardous substance No US state regulations US. New Jersey RTK - Substances: Listed substance None. US. Massachusetts RTK - Substance List None. US. Pennsylvania RTK - Hazardous Substances Distillates (petroleum), Hydrotreated Light (CAS 64742-47-8) Methyl salicylate (CAS 119-36-8) US. Rhode Island RTK None. US. California Proposition 65 California Safe Drinking Water and Toxic Enforcement Act of 1986 (Proposition 65): This material is not known to contain any chemicals currently listed as carcinogens or reproductive toxins. Volatile organic compounds (VOC) regulations EPA VOC content (40 CFR 51.100(s)) 100 % Consumer products (40 CFR 59, Subpt. C) Not regulated State Consumer products This product is regulated as a Multi-Purpose Lubricant. This product is compliant for use in all 50 states. VOC content (CA) 0 % VOC content (OTC) 0 % International Inventories Country(s) or region Inventory name On inventory (yes/no)* YesAustralia Australian Inventory of Chemical Substances (AICS) NoCanada Domestic Substances List (DSL) YesCanada Non-Domestic Substances List (NDSL) YesChina Inventory of Existing Chemical Substances in China (IECSC) NoEurope European Inventory of Existing Commercial Chemical Substances (EINECS) NoEurope European List of Notified Chemical Substances (ELINCS) NoJapan Inventory of Existing and New Chemical Substances (ENCS) YesKorea Existing Chemicals List (ECL) NoNew Zealand New Zealand Inventory NoPhilippines Philippine Inventory of Chemicals and Chemical Substances (PICCS) YesUnited States & Puerto Rico Toxic Substances Control Act (TSCA) Inventory *A "Yes" indicates that all components of this product comply with the inventory requirements administered by the governing country(s) A "No" indicates that one or more components of the product are not listed or exempt from listing on the inventory administered by the governing country(s). 16. Other information, including date of preparation or last revision Issue date 10-29-2013 7 / 8 Material name: Power Lube? Multi-Purpose Lubricant 1376 Version #: 01 Issue date: 10-29-2013 SDS US Prepared by Allison Cho Version # 01 Further information CRC # 462F HMIS? ratings Health: 1* Flammability: 2 Physical hazard: 0 Personal protection: B NFPA ratings Health: 1 Flammability: 2 Instability: 0 Disclaimer The information contained in this document applies to this specific material as supplied. It may not be valid for this material if it is used in combination with any other materials. This information is accurate to the best of CRC Industries' knowledge or obtained from sources believed by CRC to be accurate. Before using any product, read all warnings and directions on the label. For further clarification of any information contained on this (M)SDS consult your supervisor, a health & safety professional, or CRC Industries. 8 / 8 Material name: Power Lube? Multi-Purpose Lubricant 1376 Version #: 01 Issue date: 10-29-2013 SDS US