SDS Repository

sds

Collection
FJC
Description
 
Tags
Search Tag
Filename
9165_Kwik_Seal_Leak_Sealant.pdf
Source
 
Full Text
Kwik Seal A/C Stop Leak & Conditioners 1. Product and Company Identification Company Name: FJC Telephone: 704-664-3587 Address:101 Commercial Drive Mooresville, NC 28115 USA Substance Name: Kwik Seal A/C Stop Leak & Conditioners Product: 9165 Creation Date: 1-2009 Revision Date: 5-2015 Transportation Emergences: Infotrac 1-800-535-5053 Outside the US1-352-323-5000 (collect calls accepted) Contact: 704.664.3587 2. Hazards Identification Health Environmental Physical Acute Not applicable Acute Not Compressed Danger Toxicity: Toxicity: applicable Gas Skin Not applicable Chronic Not Irritation: Toxicity: applicable Skin Not applicable Sensitization: Eye: Contact with liquid may cause frostbite, ache, and eyesight loss Hazard Statements: Contains gas under pressure: may explode if heated Precautionary Statements: Danger 3. Composition/Information on Ingredients Chemical Name Cas # ENCIS # Reach Concentration Registered % Weight 1,1,1,2- 811-97-2 212-377-0 Yes 45-55 Tetrafluoroethane Mineral Oil 64741-88-4 265-090-8 Yes 40-54 Propriety Propriety Kwik Seal A/C Stop Leak & Conditioners Page 1 of 1 Inhalation: Skin Contact: Eye Contact: Ingestion: Notes for Doctor: Extinguishing Media: Special Hazards: Harmful Combustion: Products: Kwik Seal A/C Stop Leak & Conditioners 4. First Aid Measures Move from the exposed area immediately, supply artificial respiration if necessary. Seek medical attention immediately. Simple asphyxiate If on skin or hair remove/take off immediately all contaminated clothing rinse skin with water/shower If frostbite or freezing occur, gently warm the area with warm (47.1 ? C) water, and wrap the area with in soft bandage. Seek medical attention immediately. If no frostbite or freezing then wash the area with soap and water to remove contaminate. Flush eyes with tempered water for at least 15 minutes. Seek medical attention immediately. Treat based on the symptoms Seek medical attention immediately. There are no antidotes for this material, treatment is based on symptoms. 5. Fire Fighting Measures In case of fire use powder fire extinguishers, CO2 can be used water or fog can be used for a blaze. Container may explode or burst if exposed to heat, sparks or flames. Carbon Monoxide and Carbon Dioxide will be formed as a bi-product of combustion. 6. Accidental Release Measures Personal Protection Equipment: Non Emergency Personnel: Emergency Responders: Environmental Precautions: Methods & Materials for Containment/Cleanup: Containment: Cleanup: Other information: Reference to other: Sections: Insulated gloves, safety glasses, and air supplied breathing apparatus in high concentrations Leave the immediate area Ventilate the area Insulated gloves, safety glasses, and air supplied breathing apparatus Keep away for heat, sparks and open flames Flush the area with water, ventilate with large volumes of outside air avoid generation of sparks, heat or flames None applicable None applicable Keep away from heat, sparks and flames See section 7 for safe handling precautions and personal protective equipment. Kwik Seal A/C Stop Leak & Conditioners Page 2 of 2 Precautions for Safe Handling: Protective Measures: Fire Prevention: Aerosol & Dust Generation Prevention: Environmental Prevention: Safe Storage: Special End Use: Exposure Controls: Engineering Controls: Kwik Seal A/C Stop Leak & Conditioners 7. Handling and Storage Protect from Sunlight, store in well-ventilated place Store in flammable cabinet Keep away for heat, sparks and flames Non applicable No data available Store in clean dry area avoid heat, sparks and flames do not store in direct sun light Sealing of A/C units 8. Exposure Controls/Personal Protection Use only in well ventilated area. Follow all manufactures instructions Mechanical ventilation and other electrical equipment should be explosion proof Personal Protection Under normal use no personal protective equipment required for Equipment: accidental release see section 6 Eye and Face Safety glasses should be used whenever handling chemicals Protection: Skin Protection: Respiratory Protection: Thermal Hazards: Environmental Exposure Controls: Insulated gloves to protect from the cold In areas of high concentration/accidental releases use air supplied breathing apparatus The sudden release of pressure can generate freezing temperatures frostbite and or freezing of the skin is a risk. Do not puncture container, avoid areas where heat, sparks and flames are possible be causes of ignition sources. Kwik Seal A/C Stop Leak & Conditioners Page 3 of 3 Kwik Seal A/C Stop Leak & Conditioners 9. Physical and Chemical Properties Component 1,1,1,2 Mineral Oil Propriety Propriety Tetrafluoroethane Appearance: Liquid and vapor White Liquid Odor: Faint ethereal Ammonia Odor Threshold: Non applicable Non applicable PH: Non applicable 7.1 Melting Point/Freezing Non applicable Non applicable Point: Initial Boiling Point: -26.2 ? C Non applicable Evaporation Rate: >1 Not Determined Flammability: Non applicable Non applicable Flash point Closed Cup Non applicable >93.3 ? C Upper/Lower Non applicable Non applicable Flammability/Explosive: Vapor Pressure: 85.5 Non applicable psia@ 70 ? C Vapor Density: Air =1 3.5 Non applicable Specific Gravity: H2O= <1.22 1 @ 20 ? C Density: 7.16 lbs/gal Solubility: Non applicable Non applicable Auto-Ignition >750? C ~343.3 ? C Temperature: Decomposition Not available Not available Temperature: Reactivity: Chemical Stability: Possibility of Hazardous Reactions: Conditions to Avoid: Incompatible Materials: Hazardous Decomposition Products: Storage: 10. Stability and Reactivity Stable at normal temperature and pressure No reaction No reaction Avoid contact with heat, flame, sparks or other sources of ignition Avoid contact with strong oxidizing agents, Alkali or alkaline earth metals powdered Aluminum/Zinc etc Products of combustion may contain Carbon Monoxide and Carbon Dioxide. Store in well ventilated place keep cool Kwik Seal A/C Stop Leak & Conditioners Page 4 of 4 Acute Toxicity: Skin Corrosion/Irritation: Serious Eye Damage: Respiratory or Skin Sensitization: Germ Cell Mutagenicity: Carcinogenicity: Reproductive Toxicity: STOT Single Exposure: STOT Repeated Exposure: Aspiration Hazard: Toxicity: Persistence and Degradability: Bioaccumulative Potential: Mobility in Soil: Results of PBT/vPvB Assessment: Other Adverse effects: Waste Treatment Methods: Air: Land: Sea: Kwik Seal A/C Stop Leak & Conditioners 11. Toxicological Information No toxicity by inhalation Contact with liquid may cause frostbite, ache, and water blisters Contact with liquid may cause frostbite, ache, and eyesight loss Material is not a sensitization agent Non applicable No data available No data available May cause drowsiness or dizziness, headache, difficultly breathing, loss of consciousness No affects Simple asphyxiate in high concentration difficulty in breathing, nausea, vomiting, coma, spasm, and paralysis 12. Ecological Information No data available No data available No data available No data available No data available No data available 13. Disposal Considerations Dispose of contents/container in accordance with local/regional/national/international regulations. 14. Transport Information FJC does not ship this product by Air. Consult federal rules and regulations before shipping this product by air. Shipping name: 1,1,1,2 tetrafluoroehtane (R134a Refrigerant Gas)- Aerosol, Class: 2.2, UN #: UN1950, Exception: Can qualify for limited quantity under special provisions Other information: Non- flammable Shipping name: 1,1,1,2 tetrafluoroehtane (R134a Refrigerant Gas)- Aerosol, Class: 2.2, UN #: UN1950, Exception: Can Kwik Seal A/C Stop Leak & Conditioners Page 5 of 5 Kwik Seal A/C Stop Leak & Conditioners qualify for limited quantity under special provisions Other information: Non- flammable Notes Precautionary Label Information: Symbols: Risk Phrases: Safety Phrases: 15. Regulatory Information Contains gas under pressure: may explode if heated H280 34 None 16. Other Information To the best of our knowledge, the information contained herein is accurate. However, neither FJC assumes any liability whatsoever for the accuracy or completeness of the information contained herein. Final determination of suitability of any material is the sole responsibility of the user. All materials may present unknown hazards and should be used with caution. Although certain hazards are described herein, we cannot guarantee that these are the only hazards that exist. NO WARRANTY, EXPRESS OR IMPLIED, OF MERCHANTABILITY, FITNESS OR OTHERWISE IS MADE. In no event shall FJC or any of its subsidiaries be liable for any special, incidental or consequential damages Kwik Seal A/C Stop Leak & Conditioners Page 6 of 6