SDS Repository

sds

Collection
Penray
Description
 
Tags
Search Tag
Filename
PENOIL_11_rev_9.12.19__1_.pdf
Source
 
Full Text
FVP PENETRATING OIL 11 OZ. Safety Data Sheet Category 1 Liquefied gas Category 1 FVPPENOIL11 FVP Penetrating Oil Factory Motor Parts 1380 Corporate Center Curve Ste. 200 Eagan, MN 55121 United States (866) 387-3343 INFOTRAC 1-800-535-5053 01 Lubricant None known. Flammable aerosols Gases under pressure Aspiration hazard Not classified. 1. Identification Product number Product identifier Company information Company phone Emergency telephone US Version # Recommended use Recommended restrictions 2. Hazard(s) identification Physical hazards Health hazards OSHA defined hazards Label elements Signal word Danger Hazard statement Extremely flammable aerosol. Contains gas under pressure; may explode if heated. May be fatal if swallowed and enters airways. Precautionary statement Prevention Keep away from heat/sparks/open flames/hot surfaces. - No smoking. Do not spray on an open flame or other ignition source. Pressurized container: Do not pierce or burn, even after use. Response If swallowed: Immediately call a poison center/doctor. Do NOT induce vomiting. Storage Store locked up. Protect from sunlight. Store in a well-ventilated place. Protect from sunlight. Do not expose to temperatures exceeding 50?C/122?F. Disposal Dispose of contents/container in accordance with local/regional/national/international regulations. Hazard(s) not otherwise classified (HNOC) Combustible. Supplemental information None. 3. Composition/information on ingredients Mixtures CAS number %Common name and synonymsChemical name 64742-47-8 60 - 80Distillates (petroleum), Hydrotreated Light 106-97-8 2.5 - 10Butane 74-98-6 2.5 - 10Propane Other components below reportable levels 10 - 20 64742-61-6 1 - 2.5Slack Wax (petroleum) *Designates that a specific chemical identity and/or percentage of composition has been withheld as a trade secret. 1 / 9 Product name: FVP Penetrating Oil Product #: FVPPENOIL11 Version #: 01 Issue date: 07-03-2019 SDS US Rev. 9/12/19 4. First-aid measures Move to fresh air. Call a physician if symptoms develop or persist.Inhalation Wash off with soap and water. Get medical attention if irritation develops and persists.Skin contact Rinse with water. Get medical attention if irritation develops and persists.Eye contact Not likely, due to the form of the product.Ingestion Aspiration may cause pulmonary edema and pneumonitis.Most important symptoms/effects, acute and delayed Provide general supportive measures and treat symptomatically. Keep victim under observation. Symptoms may be delayed. Indication of immediate medical attention and special treatment needed Ensure that medical personnel are aware of the material(s) involved, and take precautions to protect themselves. General information 5. Fire-fighting measures Water fog. Alcohol resistant foam. Dry chemical powder. Dry chemicals. Carbon dioxide (CO2).Suitable extinguishing media None known.Unsuitable extinguishing media Contents under pressure. Pressurized container may explode when exposed to heat or flame. During fire, gases hazardous to health may be formed. Specific hazards arising from the chemical Firefighters must use standard protective equipment including flame retardant coat, helmet with face shield, gloves, rubber boots, and in enclosed spaces, SCBA. Special protective equipment and precautions for firefighters In case of fire: Stop leak if safe to do so. Do not move cargo or vehicle if cargo has been exposed to heat. Move containers from fire area if you can do so without risk. Cool containers exposed to heat with water spray and remove container, if no risk is involved. Containers should be cooled with water to prevent vapor pressure build up. For massive fire in cargo area, use unmanned hose holder or monitor nozzles, if possible. If not, withdraw and let fire burn out. Fire fighting equipment/instructions Use standard firefighting procedures and consider the hazards of other involved materials. Move containers from fire area if you can do so without risk. In the event of fire and/or explosion do not breathe fumes. Specific methods Extremely flammable aerosol. Contents under pressure. Pressurized container may explode when exposed to heat or flame. Combustible. General fire hazards 6. Accidental release measures Keep unnecessary personnel away. Keep people away from and upwind of spill/leak. Keep out of low areas. Many gases are heavier than air and will spread along ground and collect in low or confined areas (sewers, basements, tanks). Wear appropriate protective equipment and clothing during clean-up. Emergency personnel need self-contained breathing equipment. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Ventilate closed spaces before entering them. Local authorities should be advised if significant spillages cannot be contained. For personal protection, see section 8 of the SDS. Personal precautions, protective equipment and emergency procedures Refer to attached safety data sheets and/or instructions for use. Stop leak if you can do so without risk. Move the cylinder to a safe and open area if the leak is irreparable. Use water spray to reduce vapors or divert vapor cloud drift. Isolate area until gas has dispersed. Eliminate all ignition sources (no smoking, flares, sparks, or flames in immediate area). Keep combustibles (wood, paper, oil, etc.) away from spilled material. For waste disposal, see section 13 of the SDS. Methods and materials for containment and cleaning up Avoid discharge into drains, water courses or onto the ground.Environmental precautions 7. Handling and storage Pressurized container: Do not pierce or burn, even after use. Do not use if spray button is missing or defective. Do not spray on a naked flame or any other incandescent material. Do not smoke while using or until sprayed surface is thoroughly dry. Do not cut, weld, solder, drill, grind, or expose containers to heat, flame, sparks, or other sources of ignition. All equipment used when handling the product must be grounded. Close valve after each use and when empty. Protect cylinders from physical damage; do not drag, roll, slide, or drop. When moving cylinders, even for short distances, use a cart (trolley, hand truck, etc.) designed to transport cylinders. Suck back of water into the container must be prevented. Do not allow backfeed into the container. Purge air from system before introducing gas. Use only properly specified equipment which is suitable for this product, its supply pressure and temperature. Contact your gas supplier if in doubt. Do not re-use empty containers. Avoid prolonged or repeated contact with skin. Use only in well-ventilated areas. Wear appropriate personal protective equipment. Wash hands thoroughly after handling. Observe good industrial hygiene practices. Precautions for safe handling 2 / 9 Product name: FVP Penetrating Oil Product #: FVPPENOIL11 Version #: 01 Issue date: 07-03-2019 SDS US Level 3 Aerosol. Store locked up. Pressurized container. Protect from sunlight and do not expose to temperatures exceeding 50?C/122 ?F. Do not puncture, incinerate or crush. Do not handle or store near an open flame, heat or other sources of ignition. This material can accumulate static charge which may cause spark and become an ignition source. Store in a well-ventilated place. Cylinders should be stored upright, with valve protection cap in place, and firmly secured to prevent falling or being knocked over. Stored containers should be periodically checked for general condition and leakage. Store away from incompatible materials (see Section 10 of the SDS). Conditions for safe storage, including any incompatibilities 8. Exposure controls/personal protection Occupational exposure limits US. OSHA Table Z-1 Limits for Air Contaminants (29 CFR 1910.1000) ValueComponents Type PEL 1800 mg/m3Propane (CAS 74-98-6) 1000 ppm US. ACGIH Threshold Limit Values ValueComponents Type STEL 1000 ppmButane (CAS 106-97-8) US. NIOSH: Pocket Guide to Chemical Hazards ValueComponents Type TWA 1900 mg/m3Butane (CAS 106-97-8) 800 ppm TWA 1800 mg/m3Propane (CAS 74-98-6) 1000 ppm No biological exposure limits noted for the ingredient(s).Biological limit values Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level. Appropriate engineering controls Individual protection measures, such as personal protective equipment Face shield is recommended. Wear safety glasses with side shields (or goggles).Eye/face protection Skin protection Wear appropriate chemical resistant gloves. Suitable gloves can be recommended by the glove supplier. Hand protection Wear suitable protective clothing.Other If permissible levels are exceeded use NIOSH mechanical filter / organic vapor cartridge or an air-supplied respirator. Respiratory protection Wear appropriate thermal protective clothing, when necessary.Thermal hazards When using do not smoke. Always observe good personal hygiene measures, such as washing after handling the material and before eating, drinking, and/or smoking. Routinely wash work clothing and protective equipment to remove contaminants. General hygiene considerations 9. Physical and chemical properties Appearance Gas.Physical state Aerosol. Liquefied gas.Form Not available.Color Not available.Odor Odor threshold Not available. pH Not available. Melting point/freezing point Not available. Initial boiling point and boiling range 394.33 ?F (201.3 ?C) estimated Flash point -156.0 ?F (-104.4 ?C) Propellant estimated Evaporation rate Not available. 3 / 9 Product name: FVP Penetrating Oil Product #: FVPPENOIL11 Version #: 01 Issue date: 07-03-2019 SDS US Not available.Flammability (solid, gas) Upper/lower flammability or explosive limits Flammability limit - lower (%) 0.7 % estimated Flammability limit - upper (%) 5.9 % estimated Explosive limit - lower (%) Not available. Explosive limit - upper (%) Not available. Vapor pressure 8.23 psig @70F estimated Vapor density Not available. Relative density Not available. Solubility(ies) Solubility (water) Not available. Partition coefficient (n-octanol/water) Not available. Auto-ignition temperature 460.17 ?F (237.87 ?C) estimated Decomposition temperature Not available. Viscosity Not available. Other information Not explosive.Explosive properties Heat of combustion (NFPA 30B) 38.33 kJ/g estimated Not oxidizing.Oxidizing properties Percent volatile 11.67 % estimated Specific gravity 0.825 estimated 10. Stability and reactivity The product is stable and non-reactive under normal conditions of use, storage and transport.Reactivity Material is stable under normal conditions.Chemical stability Hazardous polymerization does not occur.Possibility of hazardous reactions Heat. Avoid temperatures exceeding the flash point. Contact with incompatible materials.Conditions to avoid Strong oxidizing agents. Nitrates. Fluorine. Chlorine.Incompatible materials No hazardous decomposition products are known.Hazardous decomposition products 11. Toxicological information Information on likely routes of exposure Inhalation No adverse effects due to inhalation are expected. Skin contact No adverse effects due to skin contact are expected. Eye contact Direct contact with eyes may cause temporary irritation. Ingestion Droplets of the product aspirated into the lungs through ingestion or vomiting may cause a serious chemical pneumonia. Symptoms related to the physical, chemical and toxicological characteristics Aspiration may cause pulmonary edema and pneumonitis. Information on toxicological effects Acute toxicity May be fatal if swallowed and enters airways. Test ResultsComponents Species Butane (CAS 106-97-8) Inhalation Acute LC50 Mouse 1237 mg/l, 120 Minutes 4 / 9 Product name: FVP Penetrating Oil Product #: FVPPENOIL11 Version #: 01 Issue date: 07-03-2019 SDS US Test ResultsComponents Species 52 %, 120 Minutes Rat 1355 mg/l Distillates (petroleum), Hydrotreated Light (CAS 64742-47-8) Dermal Acute LD50 Rabbit > 2000 mg/kg > 2000 mg/kg, 24 Hours Inhalation LC50 Rat > 7.5 mg/l, 6 Hours > 4.6 mg/l, 4 Hours Oral LD50 Rat > 5000 mg/kg Propane (CAS 74-98-6) Inhalation Acute LC50 Mouse 1237 mg/l, 120 Minutes 52 %, 120 Minutes Rat 1355 mg/l 658 mg/l/4h Slack Wax (petroleum) (CAS 64742-61-6) Dermal Acute LD50 Rabbit > 2000 mg/kg, 24 Hours Oral * Estimates for product may be based on additional component data not shown. LD50 Rat > 5000 mg/kg Prolonged skin contact may cause temporary irritation.Skin corrosion/irritation Direct contact with eyes may cause temporary irritation.Serious eye damage/eye irritation Respiratory or skin sensitization Respiratory sensitization Not a respiratory sensitizer. This product is not expected to cause skin sensitization.Skin sensitization No data available to indicate product or any components present at greater than 0.1% are mutagenic or genotoxic. Germ cell mutagenicity Carcinogenicity This product is not considered to be a carcinogen by IARC, ACGIH, NTP, or OSHA. IARC Monographs. Overall Evaluation of Carcinogenicity Not listed. OSHA Specifically Regulated Substances (29 CFR 1910.1001-1050) Not regulated. US. National Toxicology Program (NTP) Report on Carcinogens Not listed. This product is not expected to cause reproductive or developmental effects.Reproductive toxicity Specific target organ toxicity - single exposure Not classified. Specific target organ toxicity - repeated exposure Not classified. Aspiration hazard May be fatal if swallowed and enters airways. 12. Ecological information The product is not classified as environmentally hazardous. However, this does not exclude the possibility that large or frequent spills can have a harmful or damaging effect on the environment. Ecotoxicity 5 / 9 Product name: FVP Penetrating Oil Product #: FVPPENOIL11 Version #: 01 Issue date: 07-03-2019 SDS US Components Test ResultsSpecies * Estimates for product may be based on additional component data not shown. Distillates (petroleum), Hydrotreated Light (CAS 64742-47-8) Aquatic LC50Fish 2.9 mg/l, 96 hoursRainbow trout,donaldson trout (Oncorhynchus mykiss) No data is available on the degradability of this product. Persistence and degradability Bioaccumulative potential Partition coefficient n-octanol / water (log Kow) Butane 2.89 Propane 2.36 No data available.Mobility in soil Other adverse effects No other adverse environmental effects (e.g. ozone depletion, photochemical ozone creation potential, endocrine disruption, global warming potential) are expected from this component. 13. Disposal considerations Collect and reclaim or dispose in sealed containers at licensed waste disposal site. Contents under pressure. Do not puncture, incinerate or crush. Dispose of contents/container in accordance with local/regional/national/international regulations. Disposal instructions Dispose in accordance with all applicable regulations.Local disposal regulations The waste code should be assigned in discussion between the user, the producer and the waste disposal company. Hazardous waste code Dispose of in accordance with local regulations. Empty containers or liners may retain some product residues. This material and its container must be disposed of in a safe manner (see: Disposal instructions). Waste from residues / unused products Since emptied containers may retain product residue, follow label warnings even after container is emptied. Empty containers should be taken to an approved waste handling site for recycling or disposal. Do not re-use empty containers. Contaminated packaging 14. Transport information DOT UN1950UN number Aerosols, flammable, (each not exceeding 1 L capacity)UN proper shipping name 2.1Class Transport hazard class(es) -Subsidiary risk 2.1Label(s) Not applicable.Packing group Read safety instructions, SDS and emergency procedures before handling.Special precautions for user N82Special provisions 306Packaging exceptions NonePackaging non bulk NonePackaging bulk This product meets the exception requirements of section 173.306 as a limited quantity and may be shipped as a limited quantity. Until 12/31/2020, the "Consumer Commodity - ORM-D" marking may still be used in place of the new limited quantity diamond mark for packages of UN 1950 Aerosols. Limited quantities require the limited quantity diamond mark on cartons after 12/31/20 and may be used now in place of the "Consumer Commodity ORM-D" marking. IATA UN1950UN number Aerosols, flammableUN proper shipping name 2.1Class Transport hazard class(es) -Subsidiary risk 2.1Label(s) Not applicable.Packing group No.Environmental hazards 10LERG Code Read safety instructions, SDS and emergency procedures before handling. Read safety instructions, SDS and emergency procedures before handling. Special precautions for user 6 / 9 Product name: FVP Penetrating Oil Product #: FVPPENOIL11 Version #: 01 Issue date: 07-03-2019 SDS US Allowed with restrictions.Passenger and cargo aircraft Other information Allowed with restrictions.Cargo aircraft only LTD QTYPackaging Exceptions IMDG UN1950UN number AEROSOLSUN proper shipping name 2.1Class Transport hazard class(es) -Subsidiary risk NoneLabel(s) Not applicable.Packing group No.Marine pollutant Environmental hazards F-D, S-UEmS Read safety instructions, SDS and emergency procedures before handling. Read safety instructions, SDS and emergency procedures before handling. Special precautions for user LTD QTYPackaging Exceptions Not applicable.Transport in bulk according to Annex II of MARPOL 73/78 and the IBC Code DOT IATA; IMDG Avoid transport on vehicles where the load space is not separated from the driver's compartment. Ensure vehicle driver is aware of the potential hazards of the load and knows what to do in the event of an accident or an emergency. Before transporting product containers: Ensure that containers are firmly secured. Ensure cylinder valve is closed and not leaking. Ensure valve outlet cap nut or plug (where provided) is correctly fitted. Ensure valve protection device (where provided) is correctly fitted. Ensure adequate ventilation. Ensure compliance with applicable regulations. General information 15. Regulatory information This product is a "Hazardous Chemical" as defined by the OSHA Hazard Communication Standard, 29 CFR 1910.1200. US federal regulations TSCA Section 12(b) Export Notification (40 CFR 707, Subpt. D) Not regulated. CERCLA Hazardous Substance List (40 CFR 302.4) Not listed. 7 / 9 Product name: FVP Penetrating Oil Product #: FVPPENOIL11 Version #: 01 Issue date: 07-03-2019 SDS US SARA 304 Emergency release notification Not regulated. OSHA Specifically Regulated Substances (29 CFR 1910.1001-1050) Not regulated. Superfund Amendments and Reauthorization Act of 1986 (SARA) Immediate Hazard - Yes Delayed Hazard - No Fire Hazard - Yes Pressure Hazard - Yes Reactivity Hazard - No Hazard categories SARA 302 Extremely hazardous substance Not listed. NoSARA 311/312 Hazardous chemical SARA 313 (TRI reporting) Not regulated. Other federal regulations Clean Air Act (CAA) Section 112 Hazardous Air Pollutants (HAPs) List Not regulated. Clean Air Act (CAA) Section 112(r) Accidental Release Prevention (40 CFR 68.130) Butane (CAS 106-97-8) Propane (CAS 74-98-6) Not regulated.Safe Drinking Water Act (SDWA) US state regulations US. California Controlled Substances. CA Department of Justice (California Health and Safety Code Section 11100) Not listed. US. California. Candidate Chemicals List. Safer Consumer Products Regulations (Cal. Code Regs, tit. 22, 69502.3, subd. (a)) Butane (CAS 106-97-8) Slack Wax (petroleum) (CAS 64742-61-6) US. Massachusetts RTK - Substance List Butane (CAS 106-97-8) Propane (CAS 74-98-6) US. New Jersey Worker and Community Right-to-Know Act Butane (CAS 106-97-8) Propane (CAS 74-98-6) US. Pennsylvania Worker and Community Right-to-Know Law Butane (CAS 106-97-8) Propane (CAS 74-98-6) US. Rhode Island RTK Butane (CAS 106-97-8) Propane (CAS 74-98-6) US. California Proposition 65 California Safe Drinking Water and Toxic Enforcement Act of 1986 (Proposition 65): This material is not known to contain any chemicals currently listed as carcinogens or reproductive toxins. International Inventories Country(s) or region Inventory name On inventory (yes/no)* YesAustralia Australian Inventory of Chemical Substances (AICS) YesCanada Domestic Substances List (DSL) NoCanada Non-Domestic Substances List (NDSL) YesChina Inventory of Existing Chemical Substances in China (IECSC) YesEurope European Inventory of Existing Commercial Chemical Substances (EINECS) NoEurope European List of Notified Chemical Substances (ELINCS) YesJapan Inventory of Existing and New Chemical Substances (ENCS) 8 / 9 Product name: FVP Penetrating Oil Product #: FVPPENOIL11 Version #: 01 Issue date: 07-03-2019 SDS US Country(s) or region Inventory name On inventory (yes/no)* YesKorea Existing Chemicals List (ECL) NoNew Zealand New Zealand Inventory NoPhilippines Philippine Inventory of Chemicals and Chemical Substances (PICCS) YesUnited States & Puerto Rico Toxic Substances Control Act (TSCA) Inventory *A "Yes" indicates that all components of this product comply with the inventory requirements administered by the governing country(s) A "No" indicates that one or more components of the product are not listed or exempt from listing on the inventory administered by the governing country(s). 16. Other information, including date of preparation or last revision 07-03-2019Issue date Version # 01 The information provided in this Safety Data Sheet is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guidance for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process, unless specified in the text. Disclaimer Product and Company Identification: Alternate Trade NamesRevision information 9 / 9 Product name: FVP Penetrating Oil Product #: FVPPENOIL11 Version #: 01 Issue date: 07-03-2019 SDS US